Centrifugal Blower for Industrial Boiler Flue Gas Denitrification G5
Description
Basic Info.
Model NO. | G/Y5-51 8D~29.5D |
Pressure | High Pressure |
Certification | ISO |
Total Pressure | 1771-10095 PA |
Delivery Time | 15 Days |
Rotation Speed | 2900-480r/Min |
Volume Flow | 9900-583000m3/H |
Transport Package | Shipping Case Packing |
Specification | According to demand |
Trademark | Huayu |
Origin | Shandong China |
HS Code | 8414593000 |
Production Capacity | 10000/Year |
Packaging & Delivery
Package Size 2300.00cm * 1500.00cm * 1500.00cm Package Gross Weight 1000.000kgProduct Description
Centrifugal Blower For Industrial Boiler Flue Gas Denitrification G5-51 centrifugal fanProduct DescriptionGY5-51 boiler-induced draft fan is suitable for the supply and induced draft fan system of 2t/ h~670t/ h steam boilers in thermal power plants, and can also meet the performance parameters of fluidized bed furnace high-pressure head. This series of fans can also be used for dust removal, Mine ventilation, and general ventilation systems.The conveying medium of the blower is air, and the medium conveyed by the induced draft fan is flue gas or gas containing impurity particles. If the concentration of impurities is less than 200mg/ m², it can be used for more than four years. If the concentration of impurities is large, it can be used, but the service life is relatively short. The maximum operating temperature of the blower must not exceed 250°C.
Model No | G/Y5-51 8D~29.5D |
Product name | Centrifugal Fan |
Application Industries | Widely used in large and medium-size factories,steel, textile, chemical,kiln, power plants, steam boiler, air treatment equipment, hot air circulation, equipment, factory/building etc |
Rotating Speed | 1450~480rpm |
Power | 15~1600KW |
Material | Q235,Stainless steel ,other |
Total Pressure | 1771-10095Pa |
Airflow | 9900-583000M3/H |
Voltage | 380V/400V/415V/440V/450V/660V/1140V |
Frequency | 50Hz/60Hz |
Temperature Resistance | -30~600 Degrees |
Color | Blue/White/Grey/Yellow/Customized |
Package | Wooden Box/Steel frame |
Specification | Can provide according to customers requirements sizes |
Impeller Type | Backward/Forward/Radial Blade |
Efficiency(%) | Over 90% |
Exported to | All Countries |
Place of Origin | Shandong China |
Brand Name | Huayu |
Warranty | 18 Months |
After-Sales Service | Field Installation, Commissioning, and Training |
The fan is composed of the impeller, casing, air inlet, transmission group, regulating door, and other components.(1) The impeller material is forward curved blades with alternate lengths and short lengths. After the impeller is formed, it is corrected by static and dynamic balance, so the operation is stable and reliable.(2) The casing is welded into a volute casing with steel plates. A dust-cleaning door is opened on the snail plate. It is convenient to remove the dust accumulated in the blade and the casing and ensure the balance and aerodynamic performance of the impeller.(3) The air inlet is made into a convergent and streamlined overall structure, which is fixed with bolts and the front cover plate.(4) The transmission group consists of a main shaft, a water-cooled bearing box, and a coupling. The main shaft is made of high-quality steel. Rolling bearings are used, and the bearing housing has two forms: integral type and partial type.(5) The adjusting door is a device used to adjust the flow rate of the fan. The adjusting door blades are petal-shaped and axially installed in front of the air inlet. Due to the adoption of the external transmission structure, the rotation is flexible and convenient.
Product Description
Structure Impeller Type:Structure Impeller Type: Backward/Forward/radial blade Driving Mode: Direct/belt/Coupling drive train System Type: Single inlet type, Overhang type Cooling Type: Air cooling/Circulating Water cooling Bearing Lubrication Methods: Grease lubricating/Oil bath lubrication Advantages of centrifugal blower 1)High strength wear-resistant impeller anti-leaking bearing box. 2)Transmission part group consists of main shaft, bearing box, rolling bearing, pulley or coupling, etc. 3)Inlet and outlet flexible joints, dampers. 4)Inlet valve, bearing temperature and vibration device sensors, impeller cleaning nozzle are optional. 5)With single suction, backward of monoblock type blades impeller have good aerodynamic performance and reliability of smooth operation.
Applications of Induced draft fan Industrial air blower centrifugal fans
VentilatingForced ventilating, Building ventilating, Mine ventilating, Tunnel ventilating, Materials ventilating and drying. Cooling and heat dissipationForced cooling and heat dissipation, Industrial equipments cooling and heat dissipation. Air purification and industrial waste gas treatment, Air filtration system, Flue gas desulfurization, Flue gas denitrification.Boiler's air supply and exhaust (Coal-fired boiler, Biomass boiler, Garbage incinerator, CFB boiler, Stoker feed boiler.).Industrial boiler blowing air, Industrial boiler inducing air, Industrial boiler primary air, Industrial boiler secondary air. Industrial boiler waste gas desulfurization, Industrial boiler flue gas denitrification.
The following points should be paid attention to durning the process of installation:
(1) Smear some graese or machine oil on some junction surfaces in order to prevent rusting, and reduce the
difficulties when moved.
(2) When fixing the scew bolts on the junction surfaces,if there are Positioning pins,fix the Positioning pins first
then the screw blots.
(3) Check the inside of the chasssis and other cases to make sure that no tools and other substances are left in it .
Application
industrial systems such as Coal-fired power, Metallurgy, Papermaking, Cement and Glass production, Chemical industry, Material handling, Sewage treatment, Waste incineration, Subway ventilation, environment protection, mine, metallurgy, petro-chemical, tunnel,Industrial boiler and Dust removal systems etc. , and wind tunnel
FAQ
FAQ
1
Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.2. Q:What is your delivery time? A:15-35workdays, depending on the model of the fan.3
Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.4
Q: What's your warranty?
A: 12 months after arrival of the goods on site.5
Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery.